We’ve assembled the most frequently asked questions about Eversense into one place. Got a question that you can’t find the answer to? Contact us.
X-ray, CT Scan:
DO NOT wear the smart transmitter during medical x-rays or computed tomography (CT) scans. To avoid interference with results, remove the smart transmitter before undergoing medical x-ray or CT scans. Make sure your health care professional knows about your smart transmitter.
Eversense® E3 Sensor is manufactured by Senseonics across the US and Europe.
Eversense® E3 Transmitter is manufactured by Senseonics in Minnesota, USA.
Yes.
(Customer Service team – see approved talking points/script on account deletion)
In extreme temperature, the system will present a High Sensor or High Transmitter Temperature Alert. Once the condition changes back to normal operating range, the system will display glucose values again.
Transmitter:
An alert appears every 20 minutes when your smart transmitter temperature is too high.
No glucose reading is displayed until the smart transmitter temperature is within normal operating conditions.
Reduce the smart transmitter temperature by moving to a cooler environment. Once the smart transmitter temperature is below 42 °C (108 °F), it will resume displaying glucose values.
You may temporarily remove the smart transmitter to cool it down. Once the smart transmitter is back to a lower temperature, be sure to replace it over the sensor.
Sensor:
The High Sensor Temperature Alert will appear every 20 minutes when the sensor temperature is too high. No glucose reading is displayed until the sensor temperature is within normal operating conditions. Go to a cooler environment to reduce the sensor temperature. Briefly remove the smart transmitter while the sensor temperature cools to between 26 - 40° C (81 - 104 °F). Then put the smart transmitter back on to start receiving glucose values again from the sensor. When you place the smart transmitter back on the sensor site, it may take up to 10 minutes for sensor communication to re-start and for glucose readings to appear in the app.

The system is indicated (approved) for use to replace fingerstick blood glucose measurements for diabetes treatment decisions.
Pay close attention to your glucose values, symptoms, and trends. If your symptoms are different than the sensor glucose values or what the alert indicates, confirm your glucose value with a blood glucose meter test before making a treatment decision.*
To make a treatment decision, the user should consider:
When to NOT make a treatment decision:

* If you have any uncertainly in how or when to make treatment decisions, always speak with your healthcare professional.
Note: Always refer to the glucose information on your Eversense CGM App on your smartphone to make treatment decisions. Do not use a secondary display like the Apple Watch or Eversense NOW.
Eversense E3 has demonstrated excellent accuracy when you need it most - we’ve demonstrated 99% of high (180 mg/dL) and 94% of low (70 mg/dL) glucose events1 detected correctly and essentially no compression lows.2
1. Senseonics. (2023) Eversense E3 Continuous Glucose Monitoring System User Guide. LBL-6002-01-001_Rev C
2. Christiansen MP et al. A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II. DIABETES TECHNOLOGY & THERAPEUTICS 2018; 20(3):197-206
Still have questions?
The Eversense team is dedicated and ready to provide the answers and support you need. Simply click the link below.
The Eversense® E3 Continuous Glucose Monitoring (CGM) System is indicated for continually measuring glucose levels for up to 180 days in persons with diabetes age 18 and older. The system is indicated for use to replace fingerstick blood glucose (BG) measurements for diabetes treatment decisions. Fingerstick BG measurements are still required for calibration primarily one time a day after day 21, and when symptoms do not match CGM information or when taking medications of the tetracycline class. The sensor insertion and removal procedures are performed by a health care provider. The Eversense E3 CGM System is a prescription device; patients should talk to their health care provider to learn more.
The Eversense® 365 Continuous Glucose Monitoring (CGM) System is indicated for continually measuring glucose levels for up to one year in people (18 years and older) with diabetes. The system is indicated for use to replace fingerstick blood glucose (BG) measurements for diabetes treatment decisions. Fingerstick BG measurements are required for calibration one time a week after day 13, and when symptoms do not match CGM information or when taking medications of the tetracycline class. The sensor insertion and removal procedures are performed by a health care provider. The Eversense 365 CGM System is a prescription device; patients should talk to their health care provider to learn more.
For important safety information, see bit.ly/eversensesafety
Eversense, Eversense E3 Continuous Glucose Monitoring, Eversense 365 Continuous Glucose Monitoring, and the Eversense logo are trademarks of Senseonics, Incorporated. Ascensia, the Ascensia Diabetes Care logo are trademarks and/or registered trademarks of Ascensia Diabetes Care Holdings AG. All other trademarks are properties of their respective owners and are used solely for informative purposes. No relationship or endorsement should be inferred or implied.